automatic floor drain trap primer valve

Items 1 - 24 of 44 Ferguson is the #1 US plumbing supply company and a top distributor of HVAC parts, waterworks supplies, and MRO products. Compare. Precision Plumbing Products 1 2 National Pipe Thread Oil Rubbed Trap Primer Npt PPO500. Precision PROFLO 1 2 Auto Trap Primer Valve P1500 Mip PFP1500.

Where replenishment of water in floor drain traps is required, trap primer valves shall be 1 2" FIP inlet x 1 2" MIP outlet, automatic trap primer valves which activate with a 10 PSIG pressure drop between 30-150 PSIG. Water release shall be factory set. Trap primer valve shall have large port openings and a non-corrosive

A priming-water conduit from a sink water faucet unit to a floor drain p-trap is located between the faucet valve and the faucet water-outlet. valves and or electronics, such as automatic primer valves (see Prim-Rite trap primer valves, Prime Perfect trap primer valves), toilet primer valve systems (see

SPECIFICATION. Sioux Chief 695 Series PrimePerfect trap primer valves shall be used where replenishment of water in floor drain traps is required. Trap primer valve shall be ½" FIP inlet × ½" MIP outlet. Automatic trap primer valve shall activate with a 10 PSIG pressure drop between 30 150 PSIG. Water release shall be

Primes 1 or 2 floor drains; Pressure drop of 5 to 10 psig (35 to 70 kPa) required to activate the priming valve; Operating range of 35 to 75 psig (245 to 525 kPa). End Connection 1, MIP. End Connection 2, FIP. Fitting Size 1, 1 2 in. Material, Brass. Technical Information. Product Specification · Warranty. Quick Compare.

A trap primer (or trap seal primer) is a plumbing device or valve that adds water to traps. The water seals in traps are needed to prevent sewer gases from entering buildings, but because this water is exposed to the air, it is subject to evaporation over time in infrequently used floor drains, leading to the release of sewer gas

The CPO-500 Dual Flow automatic pressure drop activated trap primer valve will prime up to 4 floor drains with our patented distribution units the DU-U and the DU-4. System operating range is 20 psi minimum to 80 psi (138 to 552 kpa) maximum. The valve requires a 10 psi (70 kpa) pressure drop across the valve to

DESCRIPTION: The MI-100 is a pre-assembled electronic trap seal primer programmed to maintain the water seal of lines from the manifold to the .oor drain traps should always be sloped to ensure proper water .ow 20 models are factory set to turn the stainless steel solenoid valve on every eight hours for one second.

Automatic Trap Primer Valves - 1 2" Inlet Outlet - Pressure Drop Type. Part #: PR-500. Description: PRIME-RITE, Brass · Part #: P1-500. Description: P-1 PRIMER Electronic Floor Drain PRIME-TIME Electronic Trap Primer SURFACE MOUNT 115 Volt - 3 4'' FNPT Inlet & 1 2'' or 5 8'' Comp. Outlet (NEMA Type 1 Cabinet).

This innovative trap priming system automatically primes up to four floor drain traps using our patented water distributsion system. The PRIME-RITE requires no adjustment but must be installed on a cold water line of 1-1 2" (38mm) diameter or less. The priming valve is automatically activated when it

"Prime Perfect" Trap Seal Primer by Sioux Chief. This automatic trap primer valve replenishes evaporated water in floor drain traps to prevent the escape of sewer gases. It has large port openings to prevent clogging from sediment and debris. Water release is factory set -- no field adjustment necessary. Proudly made in the

protecting a trap seal was a water supplied trap seal primer regulated by ASSE 1018. О Main concern was backflow. All have vacuum breaker component. О Work on a pressure differential principle. Page 7. Water Trap Primer Limitations. О Contractors and engineers would locate the valve in the wrong location. О Minimal

Watts Water Safety and Flow Control Products - balancing valve, ball valve, butterfly valve, check valve, relief valve, temperature gauge and much more

Zurn manufactures a complete line of trap primers and specialty drains.

tinyurl.com ksz249n -- Prime Perfect Trap Primer Valve automatically activates to replenish evaporated water in floor drain traps to prevent the escap

Series A200 Flow-Through Trap Primers are used in commercial and residential applications to assure delivery of water to floor drain traps to prevent the evaporation of the water seal that protects a building or room from sewer gas fumes. It consists of a bronze body construction with a Celcon seat and disc. Available in

PPP PR-500 Prime-rite Primer Automatic Trap Primer ValvePrecision Plumbing ProductsThis innovative trap priming system automatically primes up to four floor drain traps using our patented water distributsion system. The PRIME-RITE requires no adjustment but must be installed on a cold water line of 1-1 2" (38mm)

PPP, Precision Plumbing Products, has a wide range of electronic automatic trap primering stations manifolded to handle from 1 to 30 traps at a time. I don''t understand, I put a floor drain in my sauna bath and since it''s seldom used I put a trap primer in it, I ran a 1 4" copper line to it like they use for

In this instance, one trap seal primer can serve both floor drain traps, omitting the need for additional trap primers, extra shutoff valves, another access door and air gap fittings, which saves time, money, and labor. They can also be installed with an electronic timer to provide automatic filling of the trap seal. In this installation

Used where trapped drains are installed in locations used infrequently or other conditions might permit water seal to evaporate. odors to escape through drain. A trap primer is recommended to compensate for evaporation while providing a water seal in the trap at all times. Product Details. Product Type: Floor Drain.